Use of Composite Timber-concrete Floors in Residential Buildings
Timber-concrete floors are widely used in the Gulf region for its resistance to hot and aggressive environment of the area. However, due to the fact that no shear connector is provided,...

Evaluation of Wood Floor Vibration Design Criteria
In the United States, floors in wood buildings are designed according to strength and deflection criteria under static uniform loads. With the introduction of engineered joist products...

Load and Resistance Factors for Bridge Design Code
The paper summarizes the code development procedures used for the new LRFD (load and resistance factor design) bridge code. The current specifications use allowable stresses and/or load...

LRFD Provisions for Wood Bridges
A project to develop a load and resistance factor design (LRFD) edition of the American Association of State Highway and Transportation Officials (AASHTO) Standard Specifications for Highway...

Unified Code Provisions for Concrete Bridges
Provisions on limiting the flexural reinforcement adopted in the new AASHTO LRFD Specification for Bridge Design are summarized (1). They address minimum and maximum levels of reinforcement...

Seismic Behavior of Type PR Steel Frames
Type PR(partially restrained 'simple framing') is one of the methods of design specified in the AISC LRFD(1986) Design code for the design of unbraced steel building frames. In this method...

Test Experience with Heavy Angle Dead End Lattice Transmission Towers
During the past three years, the Electric Power Research Institute's Transmission Line Mechanical Research Center has conducted full scale tests on three 500kV heavy angle dead end lattice...

Assessment and Upgrade of an Older Transmission Line
This paper discusses the various tools and procedures which have been used to assess and upgrade an older 130 kv tower line. The purpose of the assessment was to determine the line compliance...

Mechanical Behavior of Dowels Embedded in Concrete
In this paper an experimental investigation on the behavior of dowels embedded in concrete is described. The dowel strength under monotonic forces with two different boundary conditions...

Lateral Load Resisting Systems for Circular Buildings
The design of structural systems to economically limit inter-story drift and building acceleration for circular high rise buildings is presented within the framework of two recently constructed...

Criteria for Acceptable Wind-Induced Motions
This paper discusses criteria for evaluating acceptable wind-induced building motions. The paper draws on the results of moving room experiments and the performance of actual buildings...

Methods to Control Wind-Induced Building Motions
The wind-induced response of tall buildings can be controlled by global design modifications that can be placed in three broad categories, namely, design changes in structural systems,...

Response of Stressed Timber T - and Box-Beam Bridges
The objective of this study is to establish the strength, stiffness, and transverse load distribution factors of stressed timber T-, Bulk T-, and Box-beam bridge systems. To achieve the...

SDC Detector Foundation Requirements for the SSC
The Solenoidal Detector Collaboration (SDC) detector weighs approximately 32,000 metric tons, and its ability to perform to design specifications is directly related to its internal alignment....

Uniform Lateral Load Capacity of Infilled Frames
Three tests were conducted on 2.4 meter by 2.4 meter steel frames infilled with structural clay tile to determine the behavior and capacity when subjected to uniform lateral loads. An...

Dynamic Testing of Unreinforced Brick Masonry Infills
A significant seismic hazard may exist when unreinforced masonry infill panels fall out of their surrounding frames as a result of excessive accelerations applied normal to their plane....

Limit States Analysis of Masonry Arches
The limit states analysis of masonry arches, heretofore used only for the analysis of hinging mechanisms within the arch ring, is shown to have wider applicability. Lower and upper bounds...

A Peice-wise Linear Evaluation of Masonry Infills Subjected to Out-of-plane Seiesmic Drift
This paper summarizes the out-of-plane testing and analytical modeling of a full-scale unreinforced masonry (URM) infilled frame and a bare frame without infilling. The testing was part...

Steel-Concrete Interaction by Means of Film Sensors
By adapting a recently-developed technique based on the piezoelectrical properties of relatively thick films made of Polyvinyldifluor organic composites and extensively used in robotics,...

Load Carrying Capacity of SPC Composite Column
This paper reports the result of beam column test of a new type composite columns. High-strength precast-concrete panels (hereafter denoted as PCa-panels) are fixed to the steel square...

 

 

 

 